Error Codes
Page 14 of 18 FB08-15
Control Type: DX4
NOTE: If there is a gas failure the electronic ignition of the gas heated tumbler will only try to function one
time for approximately 10 seconds. If the detection device does not detect a flame, the ignition relay goes into
safe mode. When the drying cycle restarts, then the ignition will reoccur.
Table 7
Error Code Probable Cause Possible Corrective Actions
ESH The temperature sensor has
detected a temperature above
100
o
C.
Replace temperature sensor
Check sensor wiring
EOP The temperature sensor has
detected a temperature below 4
o
C.
Replace temperature sensor
Check sensor wiring
VEn The exhaust air is restricted
Clean lint screen
Inspect exhaust venting
rot The cylinder is not turning
Check drive belt
Check rotation sensor